SOC 2 Bridge Letter: What It Is, Who Signs It and What to Include

A bridge letter, sometimes called a gap letter, covers the time between the end of your most recent SOC 2 report period and the date a customer asks for it. Your management writes and signs it, not your auditor.

Here is what a bridge letter should contain, when customers will accept one, and how to avoid the mistakes that make them ask for more.

Last reviewed November 3, 2026 by the Cybersecurity Services team. About this site.

Why Bridge Letters Exist

A SOC 2 Type II report covers a fixed period, for example January 1 to December 31. The report itself may not be issued until weeks after the period ends, and customers review vendors all year round. When a customer asks in March, the most recent report already leaves a gap of a few months. A bridge letter fills that gap with a statement from your management about what has happened since.

Who Issues a Bridge Letter

Your company’s management issues and signs the bridge letter, usually a senior leader such as the CEO, CTO or CISO. The CPA firm that performed your SOC 2 examination does not test the gap period and does not give an opinion on the letter. As Linford & Co. explains, the letter is a management representation, not an audit report. That is why it should be accurate and specific; customers rely on it.

What to Include

  • Your company name and the report it bridges, including the report type, the service covered and the dates of the period.
  • The gap period covered, from the day after your last report period ended to the date of the letter.
  • A statement about changes. Say whether there have been material changes to the system or to the controls described in the report during the gap period. If there have been changes, describe them briefly.
  • Known issues. Disclose any significant incidents or control failures during the gap period that a customer would reasonably want to know about.
  • The next report. State when the current examination period ends and when you expect the next report.
  • A clear statement that the letter is not an audit, and that it is provided by management, not by your service auditor.
  • Signature, name, title and date.

How Long a Gap Can It Cover?

There is no AICPA rule, but customers commonly expect bridge letters to cover no more than about three months. Beyond that, many will ask for a new report rather than a longer letter. The best way to keep gaps short is to keep your audit periods back to back, so each new period starts the day after the last one ended, and to schedule fieldwork so reports are issued promptly.

Sample Bridge Letter Outline

Every company should write its own letter with its own facts, but most follow this structure:

  1. Addressed to “our customers and their auditors” or to a named customer.
  2. Reference to the most recent SOC 2 report: type, system and period.
  3. The gap period this letter covers.
  4. A statement that management is not aware of material changes to the system or controls during the gap period, or a short description of the changes that did occur.
  5. Any significant incidents or control failures relevant to the report.
  6. The current examination period and expected report date.
  7. A statement that the letter is provided by management and has not been examined by the service auditor.
  8. Signature block.

Common Mistakes

  • Letting gaps grow. If your audit periods are not continuous, no letter can cover the hole convincingly.
  • Saying “no changes” when there were changes. A new cloud provider, a major product release or a key leadership change may be material. Describe them.
  • Putting the auditor’s name on it. Mentioning the auditor who issued the report is fine; implying they reviewed the letter is not.
  • Sending it without the report. A bridge letter supplements a report. It does not replace one.

Bridge Letters and Your Budget

Because management writes the letter, the cost is mostly internal time. The bigger cost is the gap itself: if your reports run late, you will spend more time answering customer questions. Our SOC 2 cost guide covers how to plan for ongoing annual reports, and the Type 1 vs Type 2 guide explains how report periods work.

Frequently Asked Questions

Who signs a SOC 2 bridge letter?
Your company’s management signs it, usually a senior leader such as the CEO, CTO or CISO. The service auditor does not sign it or test the gap period.
No. A bridge letter is a management statement covering the time since your last report period ended. It provides no audit assurance and is used together with the report, not instead of it.
There is no formal limit, but customers commonly expect no more than about three months. For longer gaps, expect them to ask for a new report.
Bridge letters are mostly used with Type II reports, which cover a period. A Type I report covers a single date, so customers usually ask when your Type II will be available instead.
Mostly internal time, since management writes it. Some companies ask their advisors or legal counsel to review the wording.

Keep Your SOC 2 Reports Current

Get an honest scope, timeline and price for your environment.

Cybersecurity Services helps teams plan continuous audit periods so gaps stay short and customer reviews stay simple. Book a free 30-minute scoping call. Learn more about our SOC 2 readiness consulting.